{"id":1521,"date":"2026-03-07T13:10:21","date_gmt":"2026-03-07T13:10:21","guid":{"rendered":"https:\/\/ddcsolutions.com\/?p=1521"},"modified":"2026-06-26T16:38:25","modified_gmt":"2026-06-26T16:38:25","slug":"gpuvault-spec-sheet","status":"publish","type":"post","link":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/","title":{"rendered":"GPUVault Spec Sheet"},"content":{"rendered":"<p class=\"p1\" style=\"text-align: left;\"><span class=\"s1\">Need to deploy <\/span><b>extreme-density GPU infrastructure in constrained or retrofit environments<\/b><span class=\"s1\">?<\/span><\/p>\n<p class=\"p3\" style=\"text-align: left;\">The <span class=\"s2\"><b>DDC GPUVault Rack Containment Unit<\/b><\/span> is purpose-built for next-generation AI deployments that demand <span class=\"s2\"><b>ultra-high-density liquid cooling and maximum GPU protection<\/b><\/span>. Designed as a <span class=\"s2\"><b>fully water-cooled containment system<\/b><\/span>, GPUVault delivers up to <span class=\"s2\"><b>200kW of heat removal per cabinet (100kW per side)<\/b><\/span>, making it ideal for AI training clusters and high-performance GPU workloads.<\/p>\n<p class=\"p1\" style=\"text-align: left;\"><span class=\"s1\">This specification sheet details the platform\u2019s <\/span><b>liquid-cooling architecture, cabinet dimensions, coil redundancy, water flow capacity, and power configurations<\/b><span class=\"s1\">, along with operational capabilities such as <\/span><b>DCIM integration, biometric access control, and optional BMS connectivity<\/b><span class=\"s1\">. With support for <\/span><b>up to six redundant coils and high-flow liquid cooling<\/b><span class=\"s1\">, GPUVault ensures reliable performance even under the most demanding compute loads.<\/span><\/p>\n<p class=\"p3\" style=\"text-align: left;\">Available in <span class=\"s2\"><b>36\u201d and 42\u201d rack width configurations with a 52U layout<\/b><\/span>, GPUVault is engineered to accommodate <span class=\"s2\"><b>deep GPU servers while delivering 100% water-based thermal management<\/b><\/span>. The design prioritizes <span class=\"s2\"><b>retrofit deployments and constrained data center environments<\/b><\/span>, allowing operators to introduce ultra-high-density GPU infrastructure without requiring full facility redesign.<\/p>\n<p class=\"p3\" style=\"text-align: left;\">Download the full specification sheet below to explore detailed technical specifications, cooling architecture, and deployment options for AI-scale GPU infrastructure.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Need to deploy extreme-density GPU infrastructure in constrained or retrofit environments? The DDC GPUVault Rack Containment Unit is purpose-built for next-generation AI deployments that demand ultra-high-density liquid cooling and maximum GPU protection. Designed as a fully water-cooled containment system, GPUVault delivers up to 200kW of heat removal per cabinet (100kW per side), making it ideal [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1519,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[6],"tags":[],"class_list":["post-1521","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-hub"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GPUVault Spec Sheet | DDC Solutions<\/title>\n<meta name=\"description\" content=\"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GPUVault Spec Sheet | DDC Solutions\" \/>\n<meta property=\"og:description\" content=\"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/\" \/>\n<meta property=\"og:site_name\" content=\"DDC Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-07T13:10:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-26T16:38:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936-1024x579.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"579\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Selena Ivanovic\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Selena Ivanovic\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/\"},\"author\":{\"name\":\"Selena Ivanovic\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/#\\\/schema\\\/person\\\/78f13c11f251af135e13cd932213bead\"},\"headline\":\"GPUVault Spec Sheet\",\"datePublished\":\"2026-03-07T13:10:21+00:00\",\"dateModified\":\"2026-06-26T16:38:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/\"},\"wordCount\":188,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ddcsolutions.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/gpuvault-spec-sheet-e1772888917936.png\",\"articleSection\":[\"Knowledge Hub\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/\",\"url\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/\",\"name\":\"GPUVault Spec Sheet | DDC Solutions\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ddcsolutions.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/gpuvault-spec-sheet-e1772888917936.png\",\"datePublished\":\"2026-03-07T13:10:21+00:00\",\"dateModified\":\"2026-06-26T16:38:25+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/#\\\/schema\\\/person\\\/78f13c11f251af135e13cd932213bead\"},\"description\":\"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ddcsolutions.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/gpuvault-spec-sheet-e1772888917936.png\",\"contentUrl\":\"https:\\\/\\\/ddcsolutions.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/gpuvault-spec-sheet-e1772888917936.png\",\"width\":1878,\"height\":1062},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/gpuvault-spec-sheet\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ddcsolutions.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"GPUVault Spec Sheet\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/#website\",\"url\":\"https:\\\/\\\/ddcsolutions.com\\\/\",\"name\":\"DDC Solutions\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ddcsolutions.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/ddcsolutions.com\\\/#\\\/schema\\\/person\\\/78f13c11f251af135e13cd932213bead\",\"name\":\"Selena Ivanovic\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g\",\"caption\":\"Selena Ivanovic\"},\"url\":\"https:\\\/\\\/ddcsolutions.com\\\/author\\\/selena5summits-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GPUVault Spec Sheet | DDC Solutions","description":"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/","og_locale":"en_US","og_type":"article","og_title":"GPUVault Spec Sheet | DDC Solutions","og_description":"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.","og_url":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/","og_site_name":"DDC Solutions","article_published_time":"2026-03-07T13:10:21+00:00","article_modified_time":"2026-06-26T16:38:25+00:00","og_image":[{"width":1024,"height":579,"url":"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936-1024x579.png","type":"image\/png"}],"author":"Selena Ivanovic","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Selena Ivanovic","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#article","isPartOf":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/"},"author":{"name":"Selena Ivanovic","@id":"https:\/\/ddcsolutions.com\/#\/schema\/person\/78f13c11f251af135e13cd932213bead"},"headline":"GPUVault Spec Sheet","datePublished":"2026-03-07T13:10:21+00:00","dateModified":"2026-06-26T16:38:25+00:00","mainEntityOfPage":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/"},"wordCount":188,"commentCount":0,"image":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#primaryimage"},"thumbnailUrl":"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936.png","articleSection":["Knowledge Hub"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/","url":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/","name":"GPUVault Spec Sheet | DDC Solutions","isPartOf":{"@id":"https:\/\/ddcsolutions.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#primaryimage"},"image":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#primaryimage"},"thumbnailUrl":"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936.png","datePublished":"2026-03-07T13:10:21+00:00","dateModified":"2026-06-26T16:38:25+00:00","author":{"@id":"https:\/\/ddcsolutions.com\/#\/schema\/person\/78f13c11f251af135e13cd932213bead"},"description":"Download the GPUVault spec sheet to explore retrofit-friendly Rack Containment Unit cooling for constrained and low-ceiling data centers.","breadcrumb":{"@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#primaryimage","url":"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936.png","contentUrl":"https:\/\/ddcsolutions.com\/wp-content\/uploads\/2026\/03\/gpuvault-spec-sheet-e1772888917936.png","width":1878,"height":1062},{"@type":"BreadcrumbList","@id":"https:\/\/ddcsolutions.com\/gpuvault-spec-sheet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ddcsolutions.com\/"},{"@type":"ListItem","position":2,"name":"GPUVault Spec Sheet"}]},{"@type":"WebSite","@id":"https:\/\/ddcsolutions.com\/#website","url":"https:\/\/ddcsolutions.com\/","name":"DDC Solutions","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ddcsolutions.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/ddcsolutions.com\/#\/schema\/person\/78f13c11f251af135e13cd932213bead","name":"Selena Ivanovic","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bce635e9ed62ff3db8eba20c512ffefb2b26e4f17139a858278cd41d3d74498d?s=96&d=mm&r=g","caption":"Selena Ivanovic"},"url":"https:\/\/ddcsolutions.com\/author\/selena5summits-com\/"}]}},"_links":{"self":[{"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/posts\/1521","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/comments?post=1521"}],"version-history":[{"count":4,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/posts\/1521\/revisions"}],"predecessor-version":[{"id":1593,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/posts\/1521\/revisions\/1593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/media\/1519"}],"wp:attachment":[{"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/media?parent=1521"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/categories?post=1521"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ddcsolutions.com\/wp-json\/wp\/v2\/tags?post=1521"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}